Noise Monitoring in
New York
Class 1 sound data for New York's noise rules.
Regulatory
The Rules That Apply to New York Projects
- NYC Noise Code (Local Law 113) — enforced by the Department of Environmental Protection, it limits construction to weekdays 7:00 a.m.–6:00 p.m. and generally holds construction noise to no more than 10 dB above ambient, measured 15 feet from the source
- Construction Noise Mitigation Plans — every New York City construction site must keep a site-specific noise mitigation plan identifying noise sources and control measures; large projects file electronically with DEP, and the plans are public
- After-Hours Variances — any night or weekend work in New York City requires an after-hours variance from the Department of Buildings, and DEP can require additional monitoring or mitigation as a condition
- Upstate ordinances — outside the city, Buffalo, Rochester, Syracuse, Albany, and other municipalities enforce their own noise ordinances, commonly with quiet hours from 10:00 p.m. to 7:00 a.m. and local decibel limits
- Federal and state rules — federal OSHA worker noise exposure requirements (29 CFR 1926.52) and FHWA 23 CFR 772 apply, alongside NYSDOT requirements and project-specific permit conditions
Why New York Teams Choose Specto
01
Ready to Deploy: US Inventory
02
Field-Ready: Configured Before Shipment
03
City Code and Local Ordinances
Who Uses Specto in New York
The New York Construction Landscape
New York Firms Working in
Noise-Sensitive Environments
Big Apple Group
Ozone Park
Hirani Group
Hicksville
Mueser Rutledge Consulting Engineers
New York City
JHB Engineering, PLLC
Montebello
Quality Control Labs
Westbury
Philibert Engineering, P.C.
Jamaica
Recommended System for New York Noise Monitoring
Svantek SV 307A Class 1 Noise Monitoring Station
Deploy once. Monitor for months.
Permanent Class 1 noise monitoring built for continuous outdoor deployment, with a patented dual-microphone system check that verifies the measurement path remotely.
Available to rent or buy from Specto's US inventory.
- Class 1 accuracy to IEC 61672-1:2013, with optional 1/1 and 1/3 octave analysis to IEC 61260-1:2014
- Noise statistics computed on the station — Ln (L1–L99), Lden, LEPd, two rolling Leq, and a complete histogram in meter mode
- Lifetime Svantek warranty on the patented MEMS microphone; three-year warranty on the instrument
- IP 54 housing rated from −20 °C to 60 °C, with 32 GB microSD storage upgradeable to 128 GB
- Patented dual-microphone system check, plus a built-in sound source producing approximately 100 dBA at 1 kHz for manual or automated verification
- Built-in 4G modem for SMS and email alarms, with results and configuration available through SvanNET
- Battery operation up to 6 days with the modem off and up to 5 days with it on, plus solar, AC, and external DC (10.5–24 V) power options
- Optional triggered audio recording and live audio streaming to support noise source identification
Our Methodology — How We Work With You
01
Discovery
We start by understanding the project, not by selling equipment. That means scope, timeline, and location; monitoring requirements and regulations; site constraints like power, connectivity, and access; and who needs the reports.
02
System Design and Preparation
We bring together the hardware, sensors, power and connectivity strategy, software setup, alerts, reporting, mounting, and accessories — then configure and prepare the system so it arrives ready for the field.
03
Delivery, Onboarding and Support
We support your team through deployment guidance, practical training, troubleshooting, reporting and alert support, and calibration and service coordination for the life of the project.
New York Noise Monitoring — Common Questions
Request Quote
For Sales, Rentals, and Quotes, please get in touch with us by filling out the form below. Our knowledgeable staff is ready and eager to assist you!