Noise Monitoring in
New Jersey
Class 1 sound data for New Jersey's state and local noise rules.
Regulatory
The Rules That Apply to New Jersey Projects
- N.J.A.C. 7:29 (state noise code) — sets maximum sound levels for commercial and industrial sources measured at a residential property line: 65 dB(A) during the day (7:00 a.m.–10:00 p.m.) and 50 dB(A) at night, plus octave-band limits
- Municipal construction ordinances — construction and demolition noise is regulated locally through the NJDEP Model Noise Control Ordinance, which municipalities adopt and NJDEP approves, setting construction hours and levels town by town
- Certified enforcement — New Jersey requires noise measurements to be taken by NJDEP-certified Noise Control Officers, trained and recertified through a state-approved course, using instruments that meet the referenced ANSI standards
- Octave-band and measurement methods — the code specifies A-weighted and octave-band criteria and defined measurement procedures (N.J.A.C. 7:29-2), so a Class 1 instrument with octave-band analysis is the right tool
- Federal rules — federal OSHA worker noise exposure requirements (29 CFR 1926.52) and FHWA 23 CFR 772 apply, alongside NJDOT requirements and project-specific permit conditions
Why New Jersey Teams Choose Specto
01
Ready to Deploy: US Inventory
02
Field-Ready: Configured Before Shipment
03
State Code and Local Ordinances
Who Uses Specto in New Jersey
The New Jersey Construction Landscape
New Jersey Firms Working in
Noise-Sensitive Environments
Paul Carpenter Associates, Inc.
Florham Park
Langan Engineering & Environmental Services
Parsippany
S.A. Engineering, LLC
Edison
Distinct Engineering Solutions, Inc.
North Brunswick
Dayton Inspection Services, Inc.
Westampton
Intertek-MT Group
Cliffwood
Recommended System for New Jersey Noise Monitoring
Svantek SV 307A Class 1 Noise Monitoring Station
Deploy once. Monitor for months.
Permanent Class 1 noise monitoring built for continuous outdoor deployment, with a patented dual-microphone system check that verifies the measurement path remotely.
Available to rent or buy from Specto's US inventory.
- Class 1 accuracy to IEC 61672-1:2013, with optional 1/1 and 1/3 octave analysis to IEC 61260-1:2014
- Noise statistics computed on the station — Ln (L1–L99), Lden, LEPd, two rolling Leq, and a complete histogram in meter mode
- Lifetime Svantek warranty on the patented MEMS microphone; three-year warranty on the instrument
- IP 54 housing rated from −20 °C to 60 °C, with 32 GB microSD storage upgradeable to 128 GB
- Patented dual-microphone system check, plus a built-in sound source producing approximately 100 dBA at 1 kHz for manual or automated verification
- Built-in 4G modem for SMS and email alarms, with results and configuration available through SvanNET
- Battery operation up to 6 days with the modem off and up to 5 days with it on, plus solar, AC, and external DC (10.5–24 V) power options
- Optional triggered audio recording and live audio streaming to support noise source identification
Our Methodology — How We Work With You
01
Discovery
We start by understanding the project, not by selling equipment. That means scope, timeline, and location; monitoring requirements and regulations; site constraints like power, connectivity, and access; and who needs the reports.
02
System Design and Preparation
We bring together the hardware, sensors, power and connectivity strategy, software setup, alerts, reporting, mounting, and accessories — then configure and prepare the system so it arrives ready for the field.
03
Delivery, Onboarding and Support
We support your team through deployment guidance, practical training, troubleshooting, reporting and alert support, and calibration and service coordination for the life of the project.
New Jersey Noise Monitoring — Common Questions
Request Quote
For Sales, Rentals, and Quotes, please get in touch with us by filling out the form below. Our knowledgeable staff is ready and eager to assist you!