Noise Monitoring in
Indiana
Class 1 sound data for Indiana's biggest building boom.
Regulatory
The Rules That Apply to Indiana Projects
- Local ordinances govern — noise is regulated city by city and county by county, and many Indiana jurisdictions apply a residential limit near 65 dB(A) by day and 55 dB(A) at night, measured at the receiving property line
- Indianapolis noise code (Revised Code Ch. 391) — the state's most detailed ordinance restricts building construction, demolition, and excavation between 7:00 p.m. and 7:00 a.m. absent an emergency permit, and is enforced by the Department of Business and Neighborhood Services
- State nuisance backstop (Indiana Code 35-45-1-3) — the disorderly conduct statute treats unreasonable noise as a criminal offense when it continues after a request to stop, a catch-all that applies statewide where no local decibel limit does
- Local hours and “plainly audible” standards — some jurisdictions use a plainly-audible test instead of a meter reading, and cities such as Carmel set explicit construction hours (7:00 a.m. to 9:00 p.m. on weekdays)
- Federal OSHA worker noise exposure requirements (29 CFR 1926.52), enforced federally in Indiana, alongside FHWA 23 CFR 772, INDOT requirements, and project-specific permit conditions
Why Indiana Teams Choose Specto
01
Ready to Deploy: US Inventory
02
Field-Ready: Configured Before Shipment
03
Applied Expertise: Local Limits, Big Projects
Who Uses Specto in Indiana
The Indiana Construction Landscape
Indiana Firms Working in
Noise-Sensitive Environments
Geosyntec Consultants, Inc.
Indianapolis
Geotill, Inc.
Fishers
American Structurepoint, Inc.
Indianapolis
Lochmueller Group
Evansville
Alt & Witzig Engineering, Inc.
Carmel
Lawson-Fisher Associates, P.C.
South Bend
Recommended System for Indiana Noise Monitoring
Svantek SV 307A Class 1 Noise Monitoring Station
Deploy once. Monitor for months.
Permanent Class 1 noise monitoring built for continuous outdoor deployment, with a patented dual-microphone system check that verifies the measurement path remotely.
Available to rent or buy from Specto's US inventory.
- Class 1 accuracy to IEC 61672-1:2013, with optional 1/1 and 1/3 octave analysis to IEC 61260-1:2014
- Noise statistics computed on the station — Ln (L1–L99), Lden, LEPd, two rolling Leq, and a complete histogram in meter mode
- Lifetime Svantek warranty on the patented MEMS microphone; three-year warranty on the instrument
- IP 54 housing rated from −20 °C to 60 °C, with 32 GB microSD storage upgradeable to 128 GB
- Patented dual-microphone system check, plus a built-in sound source producing approximately 100 dBA at 1 kHz for manual or automated verification
- Built-in 4G modem for SMS and email alarms, with results and configuration available through SvanNET
- Battery operation up to 6 days with the modem off and up to 5 days with it on, plus solar, AC, and external DC (10.5–24 V) power options
- Optional triggered audio recording and live audio streaming to support noise source identification
Our Methodology — How We Work With You
01
Discovery
We start by understanding the project, not by selling equipment. That means scope, timeline, and location; monitoring requirements and regulations; site constraints like power, connectivity, and access; and who needs the reports.
02
System Design and Preparation
We bring together the hardware, sensors, power and connectivity strategy, software setup, alerts, reporting, mounting, and accessories — then configure and prepare the system so it arrives ready for the field.
03
Delivery, Onboarding and Support
We support your team through deployment guidance, practical training, troubleshooting, reporting and alert support, and calibration and service coordination for the life of the project.
Indiana Noise Monitoring — Common Questions
Request Quote
For Sales, Rentals, and Quotes, please get in touch with us by filling out the form below. Our knowledgeable staff is ready and eager to assist you!