Noise Academy

Sound Measurements: Sound Pressure, Sound Power and Decibels

Sound measurement is the quantification of acoustic quantities such as
sound pressure, sound power, sound intensity, frequency and exposure over time.

ON THIS PAGE

Although these quantities are related, they answer different questions.

A sound level meter commonly measures sound pressure at a particular position. Sound power characterizes the acoustic emission of a source under defined operating and installation conditions. Sound intensity describes the directional flow of acoustic energy through an area.

All three can be expressed as levels in decibels, but they use different physical quantities and different reference values.

Understanding the difference is important because a machine’s sound pressure level can change simply because the microphone moves, while its sound power rating is intended to characterize the source itself under defined conditions.

Why Sound Is Measured in Decibels

The range of acoustic pressures encountered in practice is extremely wide.

Rather than using a linear pressure scale, acoustics normally uses the decibel (dB): a logarithmic unit that expresses the ratio between a measured quantity and a defined reference.

For sound pressure level, the reference is

20 micropascals (20 µPa)

For sound power level, the reference is

1 picowatt (10−12 W)

For sound intensity level, the reference is

1 picowatt per square meter (10−12 W/m²)

This means that a decibel value should always be understood together with the acoustic quantity it represents.

Several useful physical relationships follow from the logarithmic scale:

These are physical relationships.

They should not be confused with perceived loudness. The way a person experiences a change in sound depends on frequency, level, duration, spectral character and the listener, so rules such as “10 dB always sounds twice as loud” should be treated only as rough psychoacoustic approximations.

Decibel scale from 0 to 120 dB with the matching sound pressure from 20 µPa to 20 Pa, showing that each tenfold increase in pressure adds 20 dB, alongside typical A-weighted levels of familiar sources from the lowest threshold of hearing at 0 dB through a quiet rural night at 20 dB, heavy traffic at 300 ft at 60 dB and a diesel truck at 50 ft at 90 dB to a rock band at 110 dB
The logarithmic decibel scale makes very large ranges of acoustic quantities practical to compare.

The 20 µPa Reference and Sound Pressure Level

Sound pressure level is defined from the effective, or root-mean-square, sound pressure relative to a reference pressure:

Lp = 20 log₁₀(p / p₀)

where: p₀ = 20 µPa

The 20 µPa reference was selected as a conventional reference close to the hearing threshold of young listeners around 1 kHz under defined conditions.

Therefore, 0 dB SPL does not mean there is no sound. It means the measured sound pressure equals the reference pressure.

A few reference values are useful:

Sound pressure Approximate sound pressure level Context
20 µPa 0 dB SPL Standard sound-pressure reference
1 Pa 94 dB SPL Common acoustic-calibrator reference level
10 Pa 114 dB SPL Common higher acoustic-calibrator reference level

The exact values corresponding to 1 Pa and 10 Pa are approximately 93.98 dB and 113.98 dB, conventionally rounded to 94 and 114 dB.

These levels are commonly used by acoustic calibrators because they provide convenient, well-defined reference pressures.

For more detail, see Sound Level Meter Calibration.

Sound Pressure, Sound Power and Sound Intensity

These three quantities describe different aspects of an acoustic field.

Sound pressure Sound power Sound intensity
Physical quantity Pressure fluctuation at a receiver position Rate of acoustic energy emitted by a source Directional rate of acoustic energy flow per unit area
SI quantity Pa W W/m²
Level reference 20 µPa 10⁻¹² W 10⁻¹² W/m²
Typical level symbol Lp LW LI
Depends strongly on receiver distance? Yes No Yes
Influenced by room/environment? Yes Sound-power determination accounts for defined test conditions Yes
Scalar or vector quantity Scalar Scalar Vector
Typical measurement/application Environmental, occupational and community noise Equipment specification and source comparison Source ranking and sound-power determination

Sound Pressure

Sound pressure is what a microphone detects at a particular location.

It depends on factors including:

Moving the microphone can therefore change the measured sound pressure even though the source itself has not changed.

This is why environmental permits, property-line limits and occupational measurements specify where the measurement is made.

Sound Power

Sound power describes the acoustic emission of a source under defined operating and installation conditions.

Unlike sound pressure, it does not have the same direct dependence on microphone distance.

That makes sound power particularly useful for:

However, sound power should not be interpreted as completely independent of how a machine is operated or installed.

Operating load, mounting, boundaries and other installation conditions can influence the actual acoustic emission of the source.

Standardized sound-power methods therefore define measurement conditions carefully.

Sound Intensity

Sound intensity describes both the magnitude and direction of acoustic energy flow.

It is commonly measured using a specialized probe and can help:

Because intensity contains directional information, it can also be useful in situations where conventional pressure measurements are affected by sound from other nearby sources.

Sound intensity probe measuring the direction of acoustic energy flow

How Sound Pressure and Sound Power Are Related

Under simplified free-field conditions, sound pressure decreases as distance from a source increases.

For an ideal omnidirectional point source radiating into a free spherical field:

Lp ≈ LW − 20 log₁₀(r) − 11 dB

where r is distance in meters.

If an ideal source radiates over a perfectly reflecting plane into a hemisphere, the geometric constant is approximately 8 dB instead of 11 dB.

These are ideal free-field approximations, not universal prediction equations.

Actual sound propagation can differ because of:

The useful concept is simpler:

Sound power characterizes the source; sound pressure characterizes what is measured at a receiver position.

A source can therefore have one specified sound power level while producing many different sound pressure levels depending on where and how it is measured.

Two panels showing the same machine with a sound power level of 95 dB. On hard ground in a free field, the sound pressure level falls about 6 dB per doubling of distance: 87 dB at 1 m, 81 dB at 2 m, 75 dB at 4 m and 69 dB at 8 m. In a room with reflections, the levels are 89 dB at 1 m, 86 dB at 2 m, 85 dB at 4 m and 84 dB at 8 m, because reflected sound holds the level up away from the source
Sound power characterizes the source; sound pressure depends on where and how it is measured.

Decibel Arithmetic: Why 60 dB + 60 dB Is About 63 dB

Decibel levels cannot normally be added arithmetically.

For independent, incoherent sound sources expressed using comparable level quantities, the underlying energy quantities are added first:

Ltotal = 10 log₁₀(10(L₁/10) + 10(L₂/10) + …)

Two independent sources each producing 60 dB therefore combine to approximately:

63 dB

not 120 dB.

A useful shortcut is to compare the difference between two sources:

Difference between levels Add to the higher level
0 dB +3.0 dB
1 dB +2.5 dB
2 dB +2.1 dB
3 dB +1.8 dB
4 dB +1.5 dB
5 dB +1.2 dB
6 dB +1.0 dB
8 dB +0.6 dB
10 dB +0.4 dB
15 dB +0.1 dB
20 dB or more Very small contribution

This explains several practical noise-control principles.

The same logarithmic relationship can also be used in reverse for background correction, but only where the applicable measurement method permits it and there is sufficient separation between the combined and background levels.

See Background Noise and Residual Sound for that process.

Frequency Weighting: A, C and Z

Human hearing is not equally sensitive at every frequency, and many acoustic assessment methods therefore apply standardized frequency-weighting filters.

A-Weighting

A-weighting substantially reduces the contribution of low-frequency sound and is widely used in:

A-weighted results are commonly expressed as dBA or with symbols such as LAeq and LAFmax.

C-Weighting

C-weighting is considerably flatter than A-weighting through much of the audible range and retains more low-frequency contribution.

It is used in applications including:

The difference between C- and A-weighted levels can sometimes be useful as a screening indicator of low-frequency content, although it is not by itself a complete low-frequency assessment.

Z-Weighting

Z-weighting is a nominally flat standardized frequency response.

It is useful where essentially unweighted broadband or spectral information is required.

The correct weighting is determined by the applicable measurement method.

Weighting General characteristic Common applications
A Strong low-frequency attenuation Occupational, environmental and transportation noise
C Much flatter at low frequency than A Some peak and hearing-protection applications; low-frequency screening
Z Nominally flat Spectral and other assessments requiring essentially unweighted data
A, C and Z frequency-weighting curves overlaid from 10 Hz to 20 kHz on a logarithmic frequency axis; Z is flat at 0 dB, C rolls off gently at both ends, and A falls steeply below 1 kHz, reaching −39.4 dB at 31.5 Hz against −3.0 dB for C
A-weighting substantially reduces the contribution of low-frequency sound compared with C- and Z-weighting.

Instrument Class 1 status does not by itself mean every instrument must simultaneously calculate all three weightings.

That is an instrument capability that should be verified from the product specification.

For example, the SVANTEK SV 971A offers multiple weighting filters, including A, C and Z, together with IEC 61672-1:2013 Class 1 performance.

For the weighting curves themselves, see Sound Frequency.

Time Weighting, Integration and Common Acoustic Metrics

Frequency weighting determines how different frequencies contribute to a result.

Time weighting and time integration describe different ways the signal changes or accumulates over time.

Fast and Slow are standardized exponential time weightings commonly used for fluctuating sound-level indications.

Typical nominal time constants are:

Fast

125 ms

Slow

1 s

Impulse weighting has a faster rise and slower decay and should be understood as a separate standardized response rather than simply another averaging period.

Equivalent continuous sound level, or Leq, works differently.

Leq represents the time-averaged mean-square sound pressure over a defined period and does not normally use Fast or Slow time weighting as part of its standard calculation.

Common Sound Measurement Parameters

Parameter What it describes Common use
LAF/ LAS A-weighted exponentially time-weighted sound level using Fast or Slow Live readings, surveys and method-specific criteria
LAeq,T Equal-energy time-averaged A-weighted level over period T Environmental noise and many acoustic assessments
LCpeak / LZpeak Highest frequency-weighted instantaneous peak pressure during the period Impulsive or high-level event assessment where specified
LAFmax / LASmax Maximum Fast- or Slow-time-weighted level during the measurement Event and maximum-level criteria
LAE / SEL Sound exposure from an event normalized to a one-second reference Aircraft, vehicles and discrete-event comparison
Ln Level exceeded for n% of the measurement period Statistical description of environmental sound
Ldn / DNL Day-night average with a nighttime penalty Aviation and some U.S. land-use applications
Lden Day-evening-night level with evening and nighttime penalties International/environmental applications
LEX,8h Equal-energy occupational exposure normalized to eight hours Occupational exposure systems using an equal-energy approach
OSHA TWA / dose Exposure calculated using OSHA criterion level, threshold and 5 dB exchange rate U.S. OSHA occupational compliance

Several of these quantities are related, but they are not all derived from Leq in the same way.

SEL has a direct mathematical relationship to Leq and measurement duration.

LEX,8h is an equal-energy normalization of exposure to an eight-hour reference period.

However:

are distinct measurement or calculation concepts.

In particular, OSHA TWA and dose should not be treated as interchangeable with LEX,8h, because OSHA uses a 5 dB exchange-rate framework rather than a simple equal-energy calculation.

See Leq: Equivalent Continuous Sound Level and Occupational Noise Exposure for the detailed treatment of those metrics.

Choosing the Right Instrument and Measurement Method

The measurement question should determine the instrumentation.

A handheld sound level meter can be appropriate for attended surveys, building acoustics, workplace assessments and source investigation.

A personal sound exposure meter or dosimeter is designed to follow a worker and determine occupational exposure.

A weather-protected monitoring station is designed for long-term environmental and community noise measurement.

Instrument performance class should come from the governing standard, ordinance, permit, specification or monitoring plan.

IEC 61672-1 defines Class 1 and Class 2 sound level meter performance categories. Class 1 applies tighter acceptance limits across relevant performance characteristics, but Class 1 should not be presented as a universal requirement for every acoustic measurement.

Where a Class 1 instrument is required—or where tighter instrument tolerances and stronger independent evidence are appropriate—a Class 1 instrument is the appropriate choice.

See Class 1 vs Class 2 Sound Level Meters for the distinction.

Calibration, Verification and Measurement Confidence

Measurement confidence also depends on the condition and verification history of the measurement system.

For short attended measurements, applicable methods commonly use an acoustic check before the measurement series and another afterward to evaluate measurement-chain stability.

Long-term unattended monitoring requires a different approach.

A station operating for months or years should not rely only on an installation check and another check when it is eventually removed.

Instead, quality assurance may include:

Each verification event helps establish confidence in a defined interval of the monitoring record.

For Specto’s general recommended long-term workflow, see Sound Level Meter Calibration.

The governing standard, permit, contract or project monitoring plan always takes precedence over general practice.

The Practical Takeaway

There is no single number called “the sound measurement.”

Different acoustic quantities answer different questions:

Sound pressure tells you what exists at a receiver.

Sound power characterizes acoustic emission from a source under defined conditions.

Sound intensity tells you how acoustic energy is flowing.

The decibel provides a practical logarithmic way to express those quantities, while frequency weighting, time weighting and integration determine how particular acoustic metrics are calculated.

The most useful measurement is therefore not necessarily the one with the most data.

It is the measurement quantity, instrument configuration, location and duration that match the question the project needs answered.

Request Quote

For Sales, Rentals, and Quotes, please get in touch with us by filling out the form below. Our knowledgeable staff is ready and eager to assist you!