Noise Academy

Sound Frequency

Sound frequency is the number of complete pressure cycles a sound wave
produces each second, measured in hertz (Hz).

ON THIS PAGE

Frequency strongly influences the pitch we perceive and how sound interacts with barriers, structures, rooms and the atmosphere.

Real-world sound rarely consists of a single frequency. Most noise is a mixture of frequencies, and the shape of that mixture — its spectrum — helps distinguish a tonal hum from broadband hiss, understand likely sources, and determine which measurement or noise-control approach is appropriate.

Frequency is the inverse of period. A wave completing one cycle every 2 milliseconds, for example, has a frequency of:

1 / 0.002 s = 500 Hz

Frequency is also related to wavelength through the speed of sound: as frequency increases, wavelength decreases.

For more on that relationship, see Sound Waves.

Diagram relating wavelength and frequency of a sound wave
Frequency and wavelength are inversely related through the speed of sound.

The Audible Frequency Range

Human hearing is conventionally described as spanning approximately 20 Hz to 20 kHz.

That is a useful reference range, but it should not be treated as a hard biological boundary.

Hearing sensitivity varies substantially among individuals and changes with factors including:

High-frequency sensitivity generally declines with age, which is why many adults cannot hear frequencies that remain audible to younger listeners.

At the low-frequency end, the transition is also gradual. Frequencies below approximately 20 Hz are normally described as infrasound, but sufficiently high levels may still be perceived through auditory sensations, pressure, vibration or structural response.

Frequency region Approximate range General description Example applications
Infrasound Below 20 Hz Below the conventional audible range; may be perceived at sufficiently high levels through hearing, pressure or vibration Large machinery, blasting, some HVAC and industrial sources
Audible sound Approx. 20 Hz–20 kHz Conventional range of human hearing Speech, environmental noise, occupational noise, transportation, machinery
Ultrasound Above 20 kHz Above the conventional human audible range Ultrasonic cleaning, welding, leak detection and specialized industrial processes

These boundaries describe frequency ranges, not regulatory limits. Measurement requirements depend on the application and governing standard.

Professional sound level meters used for conventional occupational and environmental acoustics generally cover the frequency range needed for those applications, while specialized infrasound or ultrasound measurements may require different instrumentation.

Chart of common sound frequencies on a logarithmic axis from 20 Hz to 20 kHz: transformer hum at 120 Hz and harmonics, speaking-voice fundamentals from about 85 to 255 Hz, speech intelligibility from about 250 Hz to 8 kHz, a 520 Hz sleeping-room fire alarm, tire–pavement noise from 500 Hz to 2 kHz peaking near 1 kHz, backup alarms from 700 to 2,800 Hz, periodical cicadas from about 1 to 1.9 kHz and a smoke alarm tone near 3,100 Hz, with the octave-band scale from 31.5 Hz to 16 kHz underneath
Typical frequency content of common sources, shown against the standard octave bands.

Why Acoustics Uses Octave Bands

Human perception of frequency is approximately logarithmic.

The perceived interval from 100 Hz to 200 Hz is much more comparable to the interval from 1,000 Hz to 2,000 Hz than their absolute frequency differences would suggest.

Acoustic analysis reflects this by dividing frequency into octaves and fractional-octave bands.

An octave is commonly described as a doubling of frequency.

Modern standardized octave-band filters follow the base-10 system defined by IEC 61260-1:2014, so the exact octave ratio is slightly less than two:

G = 10(3/10) ≈ 1.9953

The familiar center frequencies — 31.5 Hz, 63 Hz, 125 Hz, 250 Hz and so on — are nominal labels. Exact band frequencies are calculated from the base-10 relationship.

A commonly used octave-band set from 31.5 Hz to 16 kHz covers most of the conventional audible range.

Common Octave-Band Frequencies

Nominal center Approx. exact center Approx. band limits A-weighting correction Typical acoustic content
31.5 Hz 31.6 Hz 22–45 Hz −39.4 dB Large fans, building rumble, low-frequency industrial sources
63 Hz 63.1 Hz 45–89 Hz −26.2 dB Engines, transformers, HVAC equipment
125 Hz 125.9 Hz 89–178 Hz −16.1 dB Speech fundamentals, machinery and HVAC components
250 Hz 251.2 Hz 178–355 Hz −8.6 dB Speech fundamentals, machinery and transportation noise
500 Hz 501.2 Hz 355–708 Hz −3.2 dB Speech energy, general machinery and traffic
1 kHz 1,000 Hz 708–1,413 Hz 0 dB Reference frequency used widely in acoustics
2 kHz 1,995 Hz 1,413–2,818 Hz +1.2 dB Speech intelligibility and many alerting sounds
4 kHz 3,981 Hz 2,818–5,623 Hz +1.0 dB Speech intelligibility; important frequency region in hearing assessment
8 kHz 7,943 Hz 5,623–11,220 Hz −1.1 dB Hiss, air leakage and high-frequency machinery noise
16 kHz 15,849 Hz 11,220–22,387 Hz −6.6 dB Very high-frequency audible content; strongly affected by atmospheric absorption

Band limits are rounded illustrations. Refer to the applicable standard where exact standardized values are required.

For a deeper explanation of band definitions and filter classes, see Octave and 1/3 Octave Band Analysis.

Third-Octave Bands and When They Help

Dividing each octave into three creates one-third-octave bands.

This gives considerably more frequency resolution than full-octave analysis while retaining the standardized constant-percentage bandwidth used throughout acoustics.

One-third-octave analysis is useful for applications including:

However, one-third-octave analysis should not be confused with narrowband machinery diagnostics.

A concentration of energy around a particular one-third-octave band can help narrow an investigation toward a likely frequency region, but identifying an individual shaft order, gear-mesh frequency or closely spaced tone may require a higher-resolution method such as FFT or order analysis.

The right frequency resolution depends on the question being asked.

Human Hearing Is Not Equally Sensitive at Every Frequency

Equal sound-pressure levels at different frequencies do not necessarily sound equally loud.

Human hearing is more sensitive through some frequency regions than others, and substantially greater low-frequency sound pressure may be required to produce the same perceived loudness as a mid-frequency tone.

This relationship is described using equal-loudness contours.

Early systematic work was carried out by Fletcher and Munson in the 1930s, with later research refining the curves.

The current international reference is ISO 226:2023, Acoustics — Normal equal-loudness-level contours.

ISO 226 describes equal-loudness relationships for pure tones under defined listening conditions and is based on otologically normal listeners within a specified young-adult population. It should therefore be understood as a standardized reference, not as a prediction of every individual’s hearing response.

Two broad characteristics are particularly useful:

The contours also change with sound level, which is one reason no single frequency-weighting curve describes every aspect of human perception.

Equal-loudness contours at 20, 40, 60 and 80 phon plus the hearing threshold, from 20 Hz to 12.5 kHz, each passing through its phon value at 1 kHz, dipping lowest around 3 to 4 kHz and rising steeply toward low frequencies
Human hearing sensitivity varies strongly with frequency; occupational noise-induced hearing loss commonly affects the 3–6 kHz region.

A, C and Z Frequency Weighting

Frequency weighting modifies the contribution of different frequencies before a broadband sound level is calculated.

Different weighting curves serve different measurement purposes.

A-Weighting

A-weighting substantially reduces the contribution of lower frequencies and, to a lesser extent, very high frequencies.

It was historically developed to approximate aspects of human frequency sensitivity at relatively low sound levels and is now widely used in:

OSHA occupational sound levels, for example, are measured using A-weighting.

 

A-weighting is commonly reported as dBA.

 

C-Weighting

C-weighting is much flatter than A-weighting over much of the audible range and retains substantially more low-frequency sound.

 

It is useful in applications including: 

The difference between C- and A-weighted levels can sometimes provide a useful screening indication that low-frequency content is significant.

It is not, by itself, a diagnosis or a universal low-frequency-noise criterion.

 

Z-Weighting

Z-weighting provides a nominally flat frequency response over the range defined by the sound level meter standard.

 

It replaced the older and inconsistently defined use of terms such as “linear” or “unweighted” in standardized sound level meter terminology.

 

Z-weighting can be useful where the objective is to examine the physical spectrum without applying A- or C-weighting, or where the governing measurement procedure specifically requires Z-weighted data.

 

The measurement method should determine which weighting is appropriate.

Typical Weighting Corrections

Nominal frequency A-weighting C-weighting Z-weighting
31.5 Hz −39.4 dB −3.0 dB 0 dB
63 Hz −26.2 dB −0.8 dB 0 dB
125 Hz −16.1 dB −0.2 dB 0 dB
250 Hz −8.6 dB 0.0 dB 0 dB
500 Hz −3.2 dB 0.0 dB 0 dB
1 kHz 0.0 dB 0.0 dB 0 dB
2 kHz +1.2 dB −0.2 dB 0 dB
4 kHz +1.0 dB −0.8 dB 0 dB
8 kHz −1.1 dB −3.0 dB 0 dB
16 kHz −6.6 dB −8.5 dB 0 dB

The difference between A- and C-weighting at low frequencies is substantial.

 

A-weighting at 31.5 Hz

−39.4 dB

C-weighting at 31.5 Hz

−3.0 dB

At 31.5 Hz, for example, A-weighting applies almost 40 dB of attenuation while C-weighting applies only about 3 dB.

That is one reason an A-weighted result alone may not fully describe some low-frequency acoustic conditions.

A, C and Z frequency-weighting curves overlaid from 10 Hz to 20 kHz on a logarithmic frequency axis; Z is flat at 0 dB, C rolls off gently at both ends, and A falls steeply below 1 kHz, reaching −39.4 dB at 31.5 Hz against −3.0 dB for C
A-weighting substantially reduces the contribution of low-frequency sound compared with C- and Z-weighting.

Instrument Capability and Frequency Weighting

Instrument class and available weighting functions are related but should not be confused.

A sound level meter’s Class 1 conformity under IEC 61672 does not automatically mean that every Class 1 instrument provides every weighting simultaneously.

Always check the instrument specification.

For example, the SVANTEK SV 971A offers A, B, C, Z and LF weighting filters, together with IEC 61672-1:2013 Class 1 performance. It also supports optional Class 1 octave and one-third-octave analysis under IEC 61260-1:2014.

The SV 307A similarly supports multiple broadband weighting filters and optional spectral analysis for unattended environmental monitoring.

 

Exact measurement ranges and spectral options should be taken from the current product datasheet rather than inferred from the instrument class alone.

Why Low-Frequency Noise Can Be Difficult to Assess

Low-frequency sound can present particular measurement and control challenges.

 

Several mechanisms contribute.

01

A-Weighting Reduces Its Contribution

A-weighting deliberately attenuates low-frequency content.

That is appropriate for many standardized acoustic metrics, but it means a single dBA result may not show how much physical sound energy exists in lower-frequency bands.

Where low-frequency content is relevant, C-weighted, Z-weighted or spectral measurements can provide useful additional context.

02

Low Frequencies Diffract More Readily

Longer wavelengths tend to diffract more readily around barriers and obstacles than shorter wavelengths.

This can make conventional barriers less effective at some low frequencies.

However, propagation depends on much more than frequency alone.

Important factors:

High-frequency atmospheric absorption is generally greater than low-frequency absorption, particularly over longer distances.

03

Building Transmission Is Frequency Dependent

Walls, façades, glazing and other building elements do not attenuate every frequency equally.

Low-frequency sound can be more difficult to control through lightweight construction, while room modes and structural resonances can cause particular frequency bands to become prominent indoors.

The exact behavior depends on the construction and room geometry, so it should be measured rather than assumed.

04

Sound Character Matters

Low-frequency, tonal or modulated sound can sometimes be especially noticeable or intrusive.

A single broadband A-weighted number may not fully describe that acoustic character.

This does not mean low-frequency noise is automatically more annoying than another sound with the same dBA value. Community response depends on multiple acoustic and non-acoustic factors.

The practical point is simpler:

When low-frequency content is important to the assessment, broadband dBA alone may not provide enough information.

Supplementary C- or Z-weighted measurements and octave or one-third-octave spectra can help explain what is happening.

Frequency and Occupational Hearing Risk

Human hearing sensitivity and susceptibility to noise-induced hearing loss are related concepts, but they are not the same thing.

Occupational noise exposure can produce a characteristic audiometric pattern commonly affecting approximately the 3–6 kHz region, often with a notch around 4 kHz.

That is different from saying that 4 kHz sound itself is universally the “most damaging” frequency.

Hearing risk depends on:

For occupational assessment, use the exposure criteria required by the applicable regulation or guidance rather than attempting to infer risk from one frequency band alone.

See Occupational Noise Exposure for the OSHA, NIOSH and exposure-dose framework.

Measuring Frequency Content in the Field

Professional sound analyzers can measure multiple frequency bands simultaneously using real-time parallel filters.

The result is a spectrum showing how acoustic energy is distributed across octave or one-third-octave bands during the same measurement period as the broadband sound level.

For standardized octave-band measurements, filter performance is addressed by IEC 61260-1:2014.

A few practical principles matter:

01

Use the weighting required by the measurement method. Z-weighted or otherwise unweighted band data is often useful for spectral assessment, but some standards specify other weighting or reporting requirements.

02

Select enough frequency resolution for the question. Octave bands are useful for broad characterization. Third-octave bands provide more detail. Narrowband FFT analysis may be required for specific machinery frequencies or detailed tonal investigation.

03

Consider the instrument noise floor by frequency. Very quiet measurements may approach the self-generated noise of the measurement system in individual bands even when the overall broadband result appears usable.

04

Record enough context. Time history, operational conditions, weather and source activity can all help explain changes in the spectrum.

05

Check the complete instrument specification. Sound level meter class, octave-filter class, available frequency range and weighting options are separate specifications.

For more detail on the measurement process, see Sound Measurements and Octave and 1/3 Octave Band Analysis.

The Practical Takeaway

Frequency tells you much more about sound than pitch alone.

It influences:

A broadband dBA result is often exactly the right metric for the applicable assessment.

But where frequency content matters — particularly for low-frequency noise, building acoustics, source investigation or control design — spectral information can explain what the single-number result cannot.

The objective is not to replace A-weighted measurements.

It is to use the frequency information appropriate to the question being asked.

Request Quote

For Sales, Rentals, and Quotes, please get in touch with us by filling out the form below. Our knowledgeable staff is ready and eager to assist you!