Noise Academy

Octave and 1/3
Octave Band Analysis

Octave band analysis divides sound into a series of frequency bands whose width is a fixed
percentage of their center frequency. Instead of showing only how loud a sound is overall,
it shows where in the frequency spectrum the acoustic energy is concentrated.

ON THIS PAGE

That distinction matters because two sources can produce the same broadband sound level while having very different frequency characteristics.

A broadband dBA measurement is useful for describing overall sound level. An octave or one-third-octave spectrum adds another layer of information that can help identify likely sources, understand how sound is behaving, select appropriate controls, and evaluate whether those controls are working.

Why a Single dBA Figure Is Not Enough

Consider two machines that both measure 85 dBA at an operator position.

One may contain strong energy around 250 Hz associated with rotating or mechanical components. Another may be dominated by broadband high-frequency sound from compressed air.

The overall A-weighted level does not show that difference clearly.

An octave or one-third-octave spectrum does.

That additional information can help direct an investigation toward:

Frequency information can also help determine which control strategies are worth investigating.

A barrier, enclosure, silencer or absorptive treatment does not perform equally at every frequency. Knowing which part of the spectrum dominates the problem helps engineers select controls that address the relevant sound.

For detailed machinery diagnostics, however, octave analysis may not provide enough frequency resolution to identify individual shaft orders, harmonics or closely spaced tones. In those applications, a higher-resolution method such as Fast Fourier Transform (FFT) analysis may be more appropriate.

One-third-octave spectrum from 31.5 Hz to 8 kHz with an otherwise flat broadband spectrum and a tonal peak at 250 Hz rising about 16 dB above neighboring bands
Two sources can have the same broadband level while looking very different in the spectrum.

Frequency Also Affects How Sound Propagates

Frequency influences how sound interacts with barriers, structures and the atmosphere.

Lower-frequency sound generally:

Higher-frequency sound

is generally more affected by atmospheric absorption and can often be attenuated more effectively by suitably designed barriers, absorptive treatments and enclosures.

These are general acoustic principles rather than universal predictions for a particular site. Distance, terrain, source directivity, ground conditions, atmospheric conditions and the construction of intervening structures all matter.

This is one reason spectral measurements are useful when investigating community or environmental noise: a broadband level alone may not reveal the frequency range responsible for an observed or reported condition.

For more on the underlying physics, see Sound Frequency.

How Octave Bands Are Defined

An octave is commonly described as a doubling of frequency.

Modern octave and fractional-octave-band filters are standardized under IEC 61260-1:2014.

The current standard uses base-10 design goals. The octave ratio is:

G = 10(3/10) ≈ 1.9953.

with a reference frequency of 1,000 Hz.

That value is extremely close to a factor of two, which is why octave bands are commonly described as doubling in frequency.

Earlier standards and historical datasets may use a base-2 convention, but IEC 61260-1:2014 removed the base-2 alternative and specifies base-10 design goals. The 2014 revision also removed the previous Class 0 performance category, leaving Class 1 and Class 2.

Familiar labels such as:

31.5 Hz

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

are nominal center frequencies.

They are convenient standardized labels. The exact mid-band frequencies and band edges are calculated from the base-10 relationship defined by the standard.

Constant Percentage Bandwidth

The defining characteristic of octave analysis is constant percentage bandwidth.

As center frequency increases, the absolute width of the band increases with it.

1/1-octave band

≈ 70.5%

of its center frequency wide

1/3-octave band

≈ 23.1%

of its center frequency wide

A 1/1-octave band is approximately 70.5% of its center frequency wide, while a 1/3-octave band is approximately 23.1% of its center frequency wide.

That means a third-octave band centered near 20 Hz covers only a few hertz, while a third-octave band near 20 kHz spans several thousand hertz.

This is fundamentally different from many FFT analyses, where frequency lines are spaced at a constant absolute interval.

Octave and fractional-octave analysis are therefore particularly well suited to acoustic applications where frequency perception and standardized band-by-band assessment matter.

FFT analysis is often more useful where the objective is to separate individual machine frequencies or closely spaced spectral components.

1/1-octave bands from 63 Hz to 8 kHz on a log frequency axis, with bandwidth growing from 44 Hz to 5.6 kHz, compared with FFT lines at a fixed 100 Hz spacing: 0 lines in the 63 Hz band rising to 56 in the 8 kHz band
Octave bands widen with frequency; FFT lines do not.

Approximate 1/1-Octave Band Edges

Nominal center frequency Approx. lower edge Approx. upper edge
31.5 Hz 22.4 Hz 44.7 Hz
63 Hz 44.7 Hz 89.1 Hz
125 Hz 89.1 Hz 177.8 Hz
250 Hz 177.8 Hz 354.8 Hz
500 Hz 354.8 Hz 707.9 Hz
1 kHz 707.9 Hz 1.413 kHz
2 kHz 1.413 kHz 2.818 kHz
4 kHz 2.818 kHz 5.623 kHz
8 kHz 5.623 kHz 11.22 kHz
16 kHz 11.22 kHz 22.39 kHz

Values are rounded illustrations of the base-10 band relationship. Refer to the applicable standard when exact standardized frequencies are required.

1/1 Octave vs 1/3 Octave Analysis

A one-third-octave analysis divides each octave into three bands, giving approximately three times the frequency resolution.

1/1 Octave 1/3 Octave
Frequency resolution Broader Approximately 3× finer
Data per spectrum Lower Higher
Useful for General spectral assessment, room-noise ratings, first-pass investigation More detailed spectral analysis, building acoustics, some tonal assessments and source investigations
SV 307A band count 10 31
SV 307A center-frequency range 31.5 Hz–16 kHz 20 Hz–20 kHz

The choice depends on the question being asked.

1/1 octave analysis is often sufficient when broad frequency regions matter.

For example:

1/3 octave analysis provides more detail and is commonly useful for:

Some tonal-noise methods use one-third-octave information, while others require narrower-band analysis. Always follow the applicable assessment standard rather than assuming one-third-octave resolution is sufficient for every tone assessment.

What IEC 61260-1 Class Means

IEC 61260-1 specifies the electroacoustic performance requirements for octave-band and fractional-octave-band filters.

Among other requirements, it controls how accurately a filter must follow its intended response and how strongly energy outside the passband is rejected.

The current standard defines Class 1 and Class 2 performance categories. Class 1 has tighter acceptance limits.

IEC 61260-1:2014 removed the Class 0 category that existed in the earlier 1995 standard. Therefore, a current instrument should not be described as having “IEC 61260-1:2014 Class 0 filters.”

It is also important to distinguish two different conformity claims:

IEC 61672-1

addresses sound level meter performance.

IEC 61260-1

addresses octave and fractional-octave filter performance.

An instrument being Class 1 under one standard does not automatically establish Class 1 performance under the other.

The required instrument and filter class should come from the governing specification or measurement method. See Class 1 vs Class 2 Sound Level Meters.

Example: Octave Analysis on the SVANTEK SV 307A

The 307A offers optional real-time

These measurements can be collected alongside the instrument’s broadband sound-level measurements rather than replacing them.

The SV 307A manual identifies 10 one-octave bands and 31 one-third-octave bands in its base-10 implementation.

This means a single environmental monitoring deployment can preserve both:

That can make later investigation of an event much easier than relying on a broadband result alone.

SV 307A Configuration Note: Why Spectrum TOTAL Can Differ from Profile Leq

This is a useful SV 307A-specific behavior to understand when reviewing data.

The instrument’s octave-analysis display includes broadband TOTAL results alongside the individual frequency bands.

According to the current SV 307A manual, the TOTAL Leq results use their own A, C and Z weighting filters, independent of the filters configured for the sound-level-meter profiles.

The octave spectra themselves are also linearly averaged.

As a result, a TOTAL value from the 1/1- or 1/3-octave analysis can differ from a Leq result displayed in a broadband measurement profile when that profile has been configured for exponential Leq integration.

For example, a profile might report:

Profile

LAeq = 71.4 dB

while the octave-analysis TOTAL displays:

TOTAL A = 71.9 dB

That does not automatically indicate calibration drift or an instrument fault.

Before troubleshooting the hardware, check the measurement configuration.

If the profile uses exponential integration while the spectrum uses linear averaging, some difference can be expected.

This is an instrument-configuration issue rather than a general rule that applies identically to every octave analyzer.

Octave Bands and NC / NR Room-Noise Ratings

Noise Criteria (NC) and Noise Rating (NR) are based on octave-band spectra.

The measured spectrum is compared band by band with a family of reference curves, which means neither rating can be properly determined from a single broadband dBA measurement.

For NC, the standard curve assessment commonly covers octave bands from 63 Hz through 8 kHz.

NR implementations can differ, so the applicable method or instrument configuration should be checked rather than assuming one universal frequency range.

For example, the SV 307A’s NR implementation uses octave-band information including the 31.5 Hz to 8 kHz range.

For a full discussion, see Noise Criteria (NC) and Noise Rating (NR).

Octave Bands and Hearing Protection

Frequency analysis can also be useful when evaluating hearing-protector attenuation.

OSHA Appendix B to 29 CFR 1910.95 provides several methods for estimating the adequacy of hearing protection.

The simpler approaches use the EPA Noise Reduction Rating (NRR), with different calculations depending on whether the exposure measurement is A- or C-weighted.

OSHA also recognizes more detailed NIOSH methods. OSHA describes NIOSH method #1B1 as the most complex and “probably the most accurate” of those methods because it uses the greatest amount of spectral information from the employee’s noise environment.

This makes intuitive sense.

Hearing protectors do not attenuate every frequency equally. A band-by-band calculation can therefore provide a more informative estimate where the workplace spectrum is strongly frequency-dependent.

That does not mean a single-number NRR is automatically invalid. OSHA specifically provides NRR-based methods for evaluating hearing-protector adequacy.

The appropriate method depends on the available measurements and the applicable occupational-noise procedure.

For more on the wider compliance framework, see Occupational Noise Exposure.

Practical Notes for Field Spectra

A few practices make spectral data considerably more useful.

01

Keep time-resolved spectra where the project needs event investigation. A single spectrum averaged over an entire day may hide how the frequency content changed during individual events. Where source investigation matters, log spectra at a time interval appropriate to the events being studied.

02

Match resolution to the question. Use octave bands where broad frequency information is sufficient. Use one-third octave or narrower methods when more detail is needed.

03

Compare source and background by frequency when the applicable method requires it. A source can dominate the overall broadband level while being partially masked by residual sound in an individual frequency band.

Where a background-correction method uses separation criteria such as the familiar 3 dB or 10 dB rules, those criteria should be applied in the way required by the governing standard — including band by band where specified.

Do not assume a broadband background margin automatically establishes the validity of every individual spectral band.

04

Document instrument configuration. Frequency weighting, integration settings, octave resolution and compensation settings can all affect how results are interpreted.

SV 307A Microphone-Compensation Note

For the SV 307A specifically, microphone and free-field compensation are configurable.

The current manual states that microphone compensation is normally enabled for acoustic measurement and describes separate Environment and Airport free-field compensation settings according to sound-incidence orientation.

It also specifies different compensation configurations for particular laboratory conformance tests.

For normal field measurements, use the configuration appropriate to the installation and manufacturer’s instructions rather than changing compensation settings simply to match another dataset.

The Practical Takeaway

A broadband sound level answers:

How much sound is there?

Octave and one-third-octave analysis add another question:

Where in the frequency spectrum is that sound energy?

That information can help:

But frequency resolution should match the task.

An octave spectrum is not a substitute for a high-resolution FFT when detailed machinery diagnostics are required, just as an FFT is not automatically the most practical way to report standardized room or environmental acoustic measurements.

The objective is to use the right analysis for the question the project needs answered.

Request Quote

For Sales, Rentals, and Quotes, please get in touch with us by filling out the form below. Our knowledgeable staff is ready and eager to assist you!