Occupational noise exposure describes the sound a worker experiences
over time. The risk is determined by both how loud the sound is and how long
the worker is exposed to it, according to the exposure criterion being applied.

ON THIS PAGE

A single sound-level reading therefore tells only part of the story. An exposure of 95 dBA lasting a few minutes and an exposure of 95 dBA lasting several hours may show the same instantaneous sound level but represent very different daily exposures.

Occupational noise criteria combine level and duration to evaluate that exposure. The calculation method, limits and exchange rate vary according to the regulation, standard or guidance being used.

In the United States, this distinction is particularly important because OSHA and NIOSH use different exchange rates and exposure criteria.

Worker wearing a shoulder-mounted noise dosimeter in an industrial environment
A dosimeter measures what the worker receives, not what the room produces.

Exchange Rate: Why Duration Changes as Sound Level Increases

The exchange rate is the change in sound level associated with a doubling or halving of allowable exposure duration.

A 3 dB exchange rate follows the equal-energy relationship: an increase of 3 dB represents approximately twice the acoustic energy, so the allowable exposure duration is halved.

NIOSH uses a 3 dB exchange rate for its Recommended Exposure Limit.

OSHA uses a 5 dB exchange rate in its occupational noise regulations. Under that system, allowable exposure duration is halved for each 5 dB increase in sound level.

The practical difference becomes substantial as sound levels rise.

For example:

Sound level OSHA PEL duration* NIOSH REL duration
85 dBA Below OSHA PEL threshold 8 hours
88 dBA Below OSHA PEL threshold 4 hours
90 dBA 8 hours Approx. 2.5 hours
94 dBA Between OSHA table values 1 hour
95 dBA 4 hours Approx. 48 minutes
100 dBA 2 hours 15 minutes

*For OSHA PEL compliance, a 90 dBA measurement threshold is used. OSHA hearing-conservation calculations use a different threshold, explained below.

The important point is not that one number can simply be substituted for the other.

OSHA is an enforceable regulatory framework. NIOSH is a health-based recommendation. Their calculations answer similar occupational-health questions using different criteria.

The two exchange rates diverge sharply above 95 dBA.

OSHA 29 CFR 1910.95

The Permissible Exposure Limit

For general industry, OSHA’s occupational noise standard establishes a permissible exposure framework based on 90 dBA over eight hours, using A-weighting, Slow response and a 5 dB exchange rate.

Table G-16 provides the following permissible exposure durations:

Sound level — dBA, Slow response Permitted duration per day
90 8 hours
92 6 hours
95 4 hours
97 3 hours
100 2 hours
102 1.5 hours
105 1 hours
110 0.5 hours
115 0.25 hour or less

When workers experience different sound levels during the day, OSHA requires the combined exposure to be considered rather than evaluating each period separately.

OSHA also states that exposure to impulsive or impact noise should not exceed 140 dB peak sound pressure level.

Where exposures exceed the Table G-16 limits, OSHA requires feasible engineering or administrative controls. Where those controls do not reduce exposure sufficiently, personal protective equipment is also required.

The Action Level

OSHA’s action level is an 8-hour TWA of 85 dBA, equivalent to a 50% OSHA dose.

Reaching the action level does not mean the 90 dBA PEL has necessarily been exceeded.

Instead, for covered general-industry workplaces, it triggers the requirements of OSHA’s hearing conservation program, including exposure monitoring, audiometric testing, hearing protectors, training and recordkeeping.

Criterion Level, Exchange Rate and Threshold Are Different Things

This distinction is important when configuring a dosimeter.

OSHA uses:

Criterion level

90 dBA;

Exchange rate

5 dB;

PEL measurement threshold

90 dBA; and

hearing-conservation measurement threshold

80 dBA.

The criterion level remains 90 dBA in both cases.

The threshold determines which sound levels the dosimeter includes in the dose calculation.

OSHA specifically confirms that the 80 dBA threshold is used for hearing-conservation measurements, while the 90 dBA threshold is used for PEL compliance.

This means two dosimeters configured differently can produce different dose results from the same workplace sound environment even though both use OSHA’s 90 dBA criterion level and 5 dB exchange rate.

That is why the instrument configuration should always be documented with the result.

OSHA Dose and TWA

OSHA expresses accumulated exposure as a percentage dose.

For exposure to several different levels during a shift:

D = 100 × (C₁/T₁ + C₂/T₂ + … + Cₙ/Tₙ)

where:

For the 5 dB exchange relationship:

T = 8 / 2((L − 90)/5)

where L is the sound level in dBA.

OSHA dose can be converted to an 8-hour TWA using:

TWA = 16.61 × log₁₀(D/100) + 90

Therefore:

100% dose = 90 dBA TWA

50% dose = 85 dBA TWA

The dose approach is useful because a personal dosimeter can accumulate exposure as a worker moves among different tasks and sound environments during the day.

OSHA, NIOSH and ACGIH: Different Purposes, Different Criteria

These three frameworks are commonly discussed together, but they do not have the same legal status.

OSHA NIOSH ACGIH
Primary role Federal workplace regulation Occupational-health recommendation Professional industrial-hygiene guidance
8-hour criterion / limit 90 dBA PEL 85 dBA REL 85 dBA TLV*
Hearing-conservation trigger 85 dBA action level — —
Exchange rate 5 dB 3 dB 3 dB*
85 dBA 50% OSHA dose 8 h 8 h*
88 dBA Depends on threshold/configuration 4 h 4 h*
91 dBA OSHA 5 dB system 2 h 2 h*
94 dBA OSHA 5 dB system 1 h 1 h*
100 dBA 2 h under Table G-16 15 min 15 min*
Legal status Enforceable for covered workplaces Recommended exposure limit Professional guideline

NIOSH recommends 85 dBA over eight hours using a 3 dB exchange rate. At 88 dBA, recommended exposure falls to four hours; at 91 dBA, two hours; at 94 dBA, one hour; and at 100 dBA, 15 minutes.

ACGIH Threshold Limit Values are professional industrial-hygiene guidance rather than regulations or consensus standards. ACGIH specifically states that TLVs are guidelines and are not developed as legal standards.

A Note on Construction

The detailed hearing-conservation provisions in 29 CFR 1910.95 discussed above apply to general industry.

Construction has separate OSHA requirements under 29 CFR 1926.52 and 1926.101.

The construction noise standard uses the same basic Table D-2 permissible-exposure values — including 90 dBA for eight hours — but its hearing-conservation requirements are not identical to the general-industry program described above.

Always identify which OSHA standard applies to the workplace being evaluated.

Equal-Energy Exposure: LEX,8h and LEPd

Outside OSHA’s 5 dB regulatory system, occupational exposure is often expressed using an equal-energy quantity normalized to an eight-hour working day.

One common form is:

LEX,8h = Leq + 10 · log₁₀(Te / T8h)

where:

Because this calculation derives from Leq, it follows the 3 dB equal-energy principle.

That makes it fundamentally different from an OSHA TWA calculated using OSHA’s 5 dB exchange rate.

An OSHA TWA and an LEX,8h calculated from the same sound history can therefore produce different values.

Always report which exposure metric and criterion were used.

For more detail on energy averaging, see Leq: Equivalent Continuous Sound Level.

Measuring Occupational Noise: Dosimetry and Area Monitoring

Two common measurement approaches are personal dosimetry and area sound-level measurement.

They answer different questions.

Personal Noise Dosimetry

A noise dosimeter is worn by the worker, with the microphone positioned in the hearing zone.

 

It follows the employee throughout the sampling period and accumulates exposure as the worker moves among tasks, equipment and work areas.

 

This makes personal dosimetry particularly useful for workers whose exposure varies substantially during the shift, including:

For these applications, dosimetry often provides the most direct measurement of the worker’s personal exposure.

 

It is not, however, the only valid occupational measurement method. Representative sound-level measurements can also be used where they adequately characterize the employee’s exposure.

Area Sound-Level Measurements

Area monitoring uses a sound level meter to characterize a particular workplace, task, machine or zone.

It is useful for:

Area measurements do not follow a mobile worker through changing sound environments in the same way a personal dosimeter does, but they can support exposure assessment when the worker’s location and activity pattern are adequately understood.

Adding octave or one-third-octave analysis can also help identify dominant frequency bands when designing engineering controls such as enclosures, barriers, silencers or damping treatments.

Configuring a Dosimeter for OSHA Measurements

Instrument settings matter as much as instrument placement.

For OSHA general-industry measurements:

Setting PEL / engineering-control assessment Hearing-conservation assessment
Criterion level 90 dBA 90 dBA
Exchange rate 5 dB 5 dB
Threshold 90 dBA 80 dBA
Frequency weighting A A
Time weighting Slow Slow

The distinction between the 80 and 90 dBA thresholds can have a significant effect where much of a worker’s shift is spent in the 80–89 dBA range.

A dosimeter capable of running multiple simultaneous profiles can be useful because different exposure criteria can be recorded during the same shift without relying on a single configuration.

Personal Sound Exposure Meter Standards

Personal noise dosimeters are specialized measurement instruments.

 The current international standard is IEC 61252:2025, Electroacoustics — Personal sound exposure meters.

The 2025 edition is a substantial technical revision. It now includes:

This means personal sound exposure meters should no longer be described simply as instruments whose performance is “anchored to Class 2” under the older framework.

In the United States, ASA/ANSI S1.25-1991 (R2024) provides specifications for personal noise dosimeters and supports 3, 4 and 5 dB exchange rates.

Product Conformity and Standard Editions

A current standard edition and an individual product’s declared conformity are not automatically the same thing.

The SVANTEK SV 104A conforms to:

Example: SVANTEK SV 104A Noise Dosimeter

The SVANTEK SV 104A is designed specifically for occupational noise-exposure measurement.

Its multiple profiles are especially useful when a project needs to record more than one occupational-noise criterion during the same measurement period.

For example, an industrial hygienist may wish to preserve an OSHA exposure profile while also recording an equal-energy exposure metric for comparison.

The Hierarchy of Controls

Occupational noise should be managed using the hierarchy of controls, with controls acting on the source or exposure pathway preferred where practical.

Tier What it means Noise examples
Elimination Remove the noisy process or hazard Remove an unnecessary noisy operation
Substitution Replace it with a quieter alternative Lower-noise equipment or processes
Engineering controls Reduce noise at the source or along the path Enclosures, silencers, damping, isolation, barriers
Administrative controls Change how exposure occurs Scheduling, restricted areas, exposure-duration management
Hearing protection Reduce sound reaching the worker's ear Earplugs, earmuffs, dual protection where required
Hierarchy of controls for noise, from elimination (most effective) through substitution, engineering controls and administrative controls to hearing protection (least effective)
PPE is the last line, not the first.

Engineering controls are generally preferable because they reduce exposure without depending on individual behavior.

Hearing protection remains an important component of occupational noise control, but its effectiveness depends on appropriate selection, fit and consistent use.

Where OSHA exposures exceed the permissible limits, feasible engineering or administrative controls are required, with personal protective equipment used where necessary to reduce remaining exposure.

What an OSHA Hearing Conservation Program Includes

For covered general-industry workplaces, once employee exposures equal or exceed the OSHA action level of 85 dBA as an 8-hour TWA, 29 CFR 1910.95 requires a continuing hearing conservation program.

Key elements include:

01

Exposure monitoring.

Monitoring must represent employee exposure and be repeated when changes in production, process, equipment or controls may increase exposure.

02

Employee notification and observation.

Affected employees must be informed of monitoring results and given an opportunity to observe exposure measurements.

03

Audiometric testing.

Baseline and annual audiograms are required for employees included in the hearing conservation program.

04

Hearing protectors.

Employees must be provided appropriate hearing-protection options at no cost where required.

05

Training.

Employees in the program receive annual training addressing noise effects, hearing protectors and audiometric testing.

06

Recordkeeping.

Exposure and audiometric records must be retained according to OSHA requirements.

Baseline Audiograms

A baseline audiogram generally must be established within six months of an employee’s first exposure at or above the action level.

Where a mobile test van is used, OSHA permits the baseline to be established within one year, subject to additional hearing-protection requirements after the first six months.

Standard Threshold Shift

OSHA defines a Standard Threshold Shift (STS) as a change in hearing threshold relative to the baseline averaging 10 dB or more at 2000, 3000 and 4000 Hz in either ear.

An identified STS can trigger follow-up actions including evaluation, employee notification and changes to hearing-protection practices where required.

Record Retention

Under OSHA’s general-industry standard:

Two years

noise-exposure measurement records must be retained for two years; and

Duration of employment

audiometric test records must be retained for the duration of the affected employee’s employment.

A strong hearing conservation program therefore goes beyond taking one set of measurements.

Exposure should be reassessed when work changes, audiometric results should be reviewed, hearing protection should be appropriately selected and fitted, and the monitoring record should be detailed enough to explain how the employee’s exposure was determined.

The Practical Takeaway

Occupational noise exposure is not determined by sound level alone.

A defensible assessment depends on understanding:

For U.S. workplaces, one of the most important distinctions is that OSHA’s 5 dB regulatory dose and NIOSH’s 3 dB equal-energy recommendation are not interchangeable.

A properly configured personal dosimeter can make that complexity much easier to manage, particularly for workers whose exposure changes throughout the day.