Noise Academy
Leq: Equivalent
Continuous Sound Level
acoustic energy as a fluctuating sound measured over the same period of time.
ON THIS PAGE
That definition is doing more work than it first appears. Real-world noise is rarely steady — a shift on a shop floor, an hour beside a highway, or a night at a construction perimeter all produce sound levels that change continuously.
Leq reduces that changing sound environment to one representative energy-average value without ignoring the contribution of louder events. This is fundamentally different from simply averaging a series of decibel readings.
Leq is one of the most widely used metrics in environmental and occupational noise assessment, and it forms the basis of several other commonly used noise indicators.
The Leq Formula
For a measurement of duration T, the equivalent continuous sound level is:
Leq = 10 · log₁₀ [ (1 / T) ∫₀ᵀ ( p(t) / p₀ )² dt ]
where:
- p₀ is the reference sound pressure of 20 µPa
- p(t) is the instantaneous frequency-weighted sound pressure
The squaring is important because sound pressure squared is proportional to acoustic energy. The measurement system first accumulates that energy over the measurement period and then converts the result back into decibels.
Two practical consequences follow.
First, Leq should always be associated with a measurement period. LAeq,1h and LAeq,8h can describe very different exposure conditions, so the averaging period should be stated or defined by the governing assessment method.
Second, time weightings such as Fast and Slow are not normally part of the standard energy-average definition of Leq. They primarily affect how rapidly displayed or exponentially weighted sound levels respond to changing sound.
Why Leq Is Not an Arithmetic Average
One of the most common mistakes in noise measurement is to treat Leq as the arithmetic mean of a series of decibel readings.
That does not work because the decibel scale is logarithmic.
Consider an eight-hour shift in a light assembly area operating at 60 dBA, interrupted once by a five-minute compressed-air blowdown at 100 dBA.
| Segment | Duration | Level | Relative energy | Share of shift energy |
|---|---|---|---|---|
| Assembly work | 7 h 55 min (28,500 s) | 60 dBA | 2.85 × 10¹⁰ | 0.9% |
| Air blowdown | 5 min (300 s) | 100 dBA | 3.00 × 10¹² | 99.1% |
| Full shift | 8 h (28,800 s) | LAeq,8h = 80.2 dBA | 3.03 × 10¹² | 100% |
Arithmetic average
60.4 dBA
The time-weighted arithmetic average of the two sound levels would be only about 60.4 dBA.
Energy average
80.2 dBA
The correct energy average is approximately 80.2 dBA.
The five-minute blowdown occupies only about one percent of the shift, but it contributes approximately 99 percent of the total acoustic energy.
That is not an error in Leq. It is exactly what the metric is designed to show.
Because Leq is an energy average, relatively short periods of high sound can contribute disproportionately to the final result. This makes Leq useful for summarizing cumulative sound exposure, although other descriptors may also be needed where the timing, frequency, peaks, intermittency or character of the sound matters.
For long-term monitoring, this is also why event history and, where appropriate, audio capture can be valuable. A single event can noticeably affect a period Leq, and understanding what caused that event can be as important as the number itself.
The Weighted Variants: LAeq, LCeq and LZeq
Leq is normally qualified by a frequency weighting.
LAeq
LAeq applies A-weighting, which reduces the contribution of lower and very high frequencies to approximate the frequency sensitivity of human hearing.
It is widely used in environmental and occupational noise assessment and is one of the most commonly reported sound-level metrics.
LCeq
LCeq applies C-weighting, which retains considerably more low-frequency energy than A-weighting.
It can therefore provide useful additional information where low-frequency sound is important, such as some industrial, mechanical, entertainment or transportation sources.
Comparing A- and C-weighted measurements can help identify whether low-frequency sound deserves further investigation, but there is no single universal LAeq-to-LCeq difference that defines a low-frequency noise problem. The applicable assessment method should determine how that difference is interpreted.
LZeq
LZeq uses Z-weighting, which is essentially a flat frequency response across the specified measurement range of the instrument.
It is useful where the underlying frequency spectrum is important or where octave-band or one-third-octave-band analysis will be carried out separately rather than relying solely on an A- or C-weighted broadband result.
For background on the logarithmic decibel scale itself, see Sound Pressure, Sound Power and Decibels.
SEL: Leq Referred to One Second
Sound Exposure Level (SEL or LE) represents the acoustic energy of an event normalized to a reference duration of one second.
The relationship is:
SEL = Leq + 10 · log₁₀(T / 1 s)
where T is the duration of the event.
For example, consider a truck pass-by lasting 20 seconds with an LAeq of 75 dBA:
SEL = 75 + 10 log₁₀(20)
SEL ≈ 88.0 dBA
SEL is particularly useful when comparing discrete events of different durations because each event is normalized to the same one-second reference period.
A short but loud event and a longer but quieter event can therefore be compared on the basis of their total acoustic energy.
This relationship also helps explain calculations used for repeated transportation events.
For example, FAA guidance shows how different combinations of event SEL and number of daily events can produce the same Day-Night Average Sound Level. Increasing the number of equivalent events by a factor of ten adds 10 dB to the total energy, meaning each individual event can be 10 dB lower while producing the same cumulative result.
LEX,8h, LEPd and the U.S. Exchange-Rate Difference
Occupational noise exposure is frequently normalized to an eight-hour working day.
An equal-energy daily exposure level can be expressed as:
LEX,8h = Leq + 10 · log₁₀(Te / T8h)
where:
- Te is the actual exposure duration; and
- T8h is eight hours, or 28,800 seconds.
For example, a worker exposed to LAeq 92 dBA for six hours would have:
LEX, 8h ≈ 90.8 dBA
The important point for U.S. users is that an equal-energy LEX,8h calculation is not the same as OSHA’s occupational noise TWA calculation.
OSHA uses:
- a permissible exposure limit of 90 dBA as an 8-hour TWA;
- a hearing-conservation action level of 85 dBA; and
- a 5 dB exchange rate.
Under a 5 dB exchange rate, the permitted exposure duration halves for every 5 dB increase in sound level.
NIOSH, by comparison, recommends an exposure limit of 85 dBA over eight hours with a 3 dB exchange rate, which follows the equal-energy principle.
Under a 3 dB exchange rate, doubling the acoustic energy increases the level by 3 dB and halves the permitted exposure duration.
An OSHA TWA and an equal-energy LEX,8h calculated from the same sound environment can therefore produce different numbers, particularly when exposure varies significantly over the day.
Always identify which exposure convention or regulatory method has been used.
Instrument Configuration: Linear vs Exponential Leq Integration
For standard Leq measurements, time weighting such as Fast or Slow is not normally part of the basic Leq definition.
Some professional sound level meters, however, provide alternative detector or integration settings for measurement methods that specifically require them.
Svantek instruments, for example, can support linear and exponential RMS integration modes for certain calculated results.
In linear mode, the instrument integrates the true RMS energy of the signal, so the resulting Leq is independent of the Fast, Slow or Impulse setting used for displayed SPL measurements.
In exponential mode, the calculation uses an exponential detector and can therefore depend on the selected time constant.
| Result | Can depend on RMS/Leq integration configuration? | Measurement approach |
|---|---|---|
| Leq | Yes, where alternative integration modes are enabled | Linear RMS or exponential according to configuration |
| SEL / LE | Yes | Derived from integrated sound energy |
| LEX,8h / LEPd | Yes | Derived from integrated sound energy |
| Ln statistical levels | Can depend on instrument implementation/configuration | Derived from distribution of measured levels |
| Lden / Ldn calculations | Depend on the underlying period measurements | Energy combination of period levels |
| Lmax / Lmin / SPL | Determined separately | Normally exponential with selected time weighting |
| Lpeak | No Fast/Slow integration | Peak detector |
The practical lesson is straightforward:
When two professional instruments produce slightly different Leq results, check their measurement configuration as well as calibration, logging interval and microphone setup before assuming that either instrument is faulty.
The governing standard or monitoring procedure should determine which settings are appropriate.
The Wider Leq Family
Several common noise descriptors are built from the same energy-averaging principles as Leq.
Rolling Leq
| Metric | What it represents | Relationship |
|---|---|---|
| SEL / LE | Event sound energy normalized to one second | SEL = Leq + 10 log(T / 1 s) |
| LEX,8h / LEPd | Occupational exposure normalized to an 8-hour day | LEX,8h = Leq + 10 log(Te / 28,800 s) |
| Rolling Leq | Leq calculated continuously over a moving time window | Window length defined by the monitoring configuration |
| Ln — L10, L50, L90 etc. | Statistical sound levels | Derived from the distribution of measured levels |
| Lden | Day-evening-night environmental indicator | Combines day, evening and night periods with +5 dB evening and +10 dB night penalties |
| Ldn / DNL | Day-night average sound level | Combines day and night periods with a +10 dB nighttime penalty |
Rolling Leq
A rolling Leq recalculates the energy-average level over a moving time window.
For example, a system could continuously calculate the previous 15-minute or one-hour Leq as new data arrives.
This can be useful for alerting because it allows project teams to see whether recent sound levels are approaching a project threshold without waiting for the end of the full monitoring period.
Projected Leq
Some monitoring instruments and software platforms also provide projected Leq functions.
These are application-specific forecasting tools rather than a separate universal acoustic descriptor.
A projected-Leq function uses the measurements collected so far, together with assumptions defined by the instrument or software, to estimate the likely outcome at the end of a longer assessment period.
On a construction site, for example, this can help answer a practical question:
If sound continues at approximately the current rate, are we likely to approach the project’s daily noise criterion later today?
The exact calculation and assumptions depend on the monitoring platform, so projected Leq should be interpreted according to the instrument or software documentation rather than treated as a standardized metric like Leq or SEL.
Lden and DNL Are Related — But Not Identical
Long-term community and transportation noise metrics use Leq-based energy averaging but apply different weighting conventions.
Lden, widely used in Europe, separates the day into day, evening and night periods. It applies:
- no penalty to the day period;
- a +5 dB penalty to evening sound; and
- a +10 dB penalty to nighttime sound.
DNL or Ldn, widely used in U.S. aviation and some other planning applications, does not contain a separate evening penalty. It combines day and night sound and applies a +10 dB penalty to nighttime sound.
The two metrics are therefore based on similar cumulative-energy principles but should not be treated as interchangeable.
Because their averaging periods, penalties and applications differ, Lden and DNL deserve to be interpreted according to the specific regulatory or assessment framework in which they are being used.
Measuring Leq You Can Defend
A Leq result is only as reliable as the measurement process used to produce it.
Start with the requirements of the applicable regulation, ordinance, standard, specification or monitoring plan. These should determine factors such as:
- required instrument class
- measurement duration
- microphone position
- calibration or field-check requirements
- frequency analysis
- frequency weighting
- logging interval
- meteorological limits
- time weighting where applicable
- reporting format
Instrument Class
Not every Leq measurement requires a Class 1 sound level meter.
The required instrument class should come from the governing method or project specification.
For professional environmental measurements, particularly where results may face significant client, regulatory or technical scrutiny, a Class 1 instrument can provide tighter performance limits than Class 2.
Where the Class 1 design has also undergone independent pattern or type approval, that approval provides an additional level of independent evidence behind the manufacturer’s performance claim.
The SVANTEK SV 307A, for example, is a Class 1 environmental noise monitoring station under IEC 61672-1 and has independent PTB type approval.
For more detail, see Class 1 vs Class 2 Sound Level Meters.
Calibration and Field Checks
Follow the acoustic calibration or sensitivity-check procedure required by the applicable measurement method.
Pre- and post-measurement acoustic checks are common good practice because they provide evidence that the measurement chain remained stable during the survey, but the exact requirements should come from the governing standard or procedure.
Logging Enough Detail
For longer monitoring periods, logging only the final Leq can make later investigation difficult.
Recording suitable time-history data allows users to:
- recalculate Leq for different time intervals
- correlate sound with project activities
- compare sound against weather or operational data
- investigate unusually high or low periods
- review alerts and exceedances
- identify discrete events that materially influenced the result
For attended measurements, a handheld Class 1 meter such as the SVANTEK SV 971A can provide Leq and associated acoustic parameters.
For unattended environmental noise monitoring over days, weeks or longer, a station such as the SVANTEK SV 307A can continuously record Leq, statistical levels and frequency data and can support audio recording where enabled, permitted and appropriately configured.
The result is not simply a single number.
It is a measurement record that provides the context needed to understand why the Leq changed and what was happening when it did.
For more on practical environmental noise monitoring, visit the Specto Noise Academy.